Redshopb2b

  • Lundahl 156X line isolations trafo XLR hun > XLR han
Lundahl Transformers
Varenummer: LL156X-3FX3MX

Lundahl 156X line isolations trafo XLR hun > XLR han

Levering: 1-3 dage

Kort beskrivelse

Line isolation transformator er designet til at bryde ground loops Inline type med XLR Male/Female konnektorer, der er galvanisk isoleret fra hinanden, gør det hurtigt og nemt at bryde groundloops i eksisterende anlæg.
Detaljebeskrivelse
Inkl. moms DKK 1.490,00

Detaljebeskrivelse

High Level, High Impedance Ground Isolation Unit
Balanced to Unbalanced Converter LL156X

The XLR inline transformer unit LL156X is designed for breaking up ground loops and for
balanced-to-unbalanced conversion in mobile or stationary audio systems. The unit is
magnetically shielded and contains a high impedance input transformer LL1565, with LF
saturation above +22 dBU, 40 Hz.
The two ends of the unit are galvanically isolated from each other.


Tekniske specifikationer
Lundahl LL156X fåes med flg stik:
LL156X-3FXNP2C Female XLR connector to 2-pole ‘A’-gauge 1/4” jack plug
LL156X-PHF3MX Female Phono (RCA) connector to male XLR connector
LL156X-3FXPHM Female XLR connector to Phono (RCA) male
LL156X-3FX3MX Female XLR connector to male XLR connector

Characteristics of built in transformer LL1565
Static resistance of primary: 1.6 kW
Static resistance of secondary: 1.3 kW
Core: Amorphous strip core
Max level: +22 dBU @ 40 Hz
No-load impedance (@20 dBU, 50Hz) 220 kW typically
Frequency response @ 0 dBU (source 600W, load 10kW) 4 Hz - 100 kHz +/- 0.5 dB
Distortion (THD, source 600W) < 0.2 % @ 50 Hz, 0 - 22 dBU
Loss across transformer, load 10kW / 100kW 2.2 dB / 0.3 dB
Isolation between windings: 1 kV